Temporary Bypass C-35 / C-56 
Wiring Modifications

These simple wiring modifications provide a temporary heating solution until the C-35 / C-56 can be replaced.

All wiring should be isolated before making amendments and should be carried out by a competent person.

The underfloor heating water temperature should already be commissioned to provide adequate heat output without overheating the floor finish.

Please consult Uponor if any doubt exists.

Below is a typical existing wiring detail which applies to
C-35 and C-56’s that create a heat demand.

Controller (C-35 / 56)
EWiring1


Three (3) simple wiring modifications can be made to simulate the C-35 demand relay operations. 

Option 1 

Permanent Demand Signal

• Label all manifold actuators according to their manifold loop position.

• Remove manifold actuators.

• Remove the relay wires and join permanently using a wiring block.

System will be permanently switched ON.

Manifold loops will be controlled as a single zone and ALL manifold actuators MUST be removed to
provide heat to ALL loops.
EWiring2


Option 2

Manual Switch Demand Signal

• Label all manifold actuators according to their manifold loop position.

• Remove manifold actuators.

• Remove the relay wires and wire to a manual switch.

 System can manually be switched ON/OFF.

Manifold loops will be controlled as a single zone and ALL manifold actuators MUST be removed to
provide heat to ALL loops.

EWiring2

EWiring3A


Option 3

Thermostat Switch Demand Signal

• Label all manifold actuators according to their manifold loop position.

• Remove manifold actuators.

• Remove the relay wires and wire to a volt free switching thermostat. Example given is the TP5000.

• Thermostat should be placed in a suitable location to regulate the demand based on the air temperature.

• No additional power supply cabling is required if a battery powered thermostat is used.

System is controlled by the thermostat
air temperature settings.

Manifold loops will be controlled as a single zone and ALL manifold actuators MUST be removed to 
provide heat to ALL loops

EWiring4A

tp5000opt


TP5000 Programmable Room Thermostat